MOXA SDS-G3006 Series

Industrial 6-port full Gigabit smart Ethernet switches with 4-port IEEE 802.3af/at PoE+ option

MOXA SDS-G3006 Series
8337_36733.png
8337_36734.png
8337_36735.png
8337_36736.png
8337_36737.png
8337_36738.png
8337_36739.png
  • EspecificacionesEspecificaciones
  • DescripciónDescripción
  • Más informaciónesMás informaciónes
  • PDFPDF
  • 4 IEEE 802.3af/at PoE+ standard ports
  • 36-watt output per PoE+ port in high-power mode
  • Compact and flexible housing design to fit into confined spaces
  • Web-based GUI for easy device configuration and management
  • Multi-language web GUI: English, Traditional Chinese, Simplified Chinese, Japanese, German, and French
  • Supports RSTP/STP, and MRP for network redundancy to ensure high network availability
  • EtherNet/IP, PROFINET, and Modbus TCP industrial protocols supported for easy integration and monitoring in automation HMI/SCADA systems
  • Security features based on IEC 62443
  • Rotary DIP switch can perform profile-based settings without using a web browser
  • Supports MXstudio for easy, visualized industrial network management

The SDS-G3006 smart Ethernet switch is the ideal product for IA engineers and automation machine builders to make their networks compatible with the vision of Industry 4.0. By breathing life into machines and control cabinets, the smart switch simplifies daily tasks with its easy configuration and easy installation. In addition, it is monitorable and is easy to maintain throughout the entire product life cycle.


The most frequently used automation protocols?including EtherNet/IP, PROFINET, and Modbus TCP?are embedded in the SDS-G3006 switch to provide enhanced operational performance and flexibility by making it controllable and visible from automation HMIs. It also supports a range of useful management functions, including IEEE 802.1Q VLAN, port mirroring, SNMP, warning by relay, and a multi-language Web GUI.



Additional Features and Benefits

  • IP port binding to ensure critical devices can be replaced quickly without reassigning the IP Address
  • IEEE 802.1Q VLAN to ease network planning
  • Supports the ABC-02-USB (automatic Backup Configurator) for quick system configuration backup/restore and firmware upgrade
  • Automatic warning by exception through relay output
  • Unused port lock, SNMPv3 and HTTPS to enhance network security
  • Port mirroring for online debugging and monitoring
  • Local log and the ability to export inventory files ease inventory management
  • Advanced PoE management function (PoE port setting, PD failure check, and PoE scheduling)


ProdGrafik


Specifications

    Ethernet Interface

      10/100/1000BaseT(X) Ports (RJ45 connector)
      SDS-G3006(-T) models: 6
      SDS-G3006-2GTXSFP(-T) models: 4
      SDS-G3006-4PoE-2GTXSFP(-T) models: 4
      Auto negotiation speed
      Full/Half duplex mode
      Auto MDI/MDI-X connection

      Combo Ports (10/100/1000BaseT(X) or 100/1000BaseSFP)
      SDS-G3006-2GTXSFP(-T) models: 2
      SDS-G3006-4PoE-2GTXSFP(-T) models: 2

      PoE Ports (10/100/1000BaseT(X), RJ45 connector)
      SDS-G3006-4PoE-2GTXSFP(-T) models: 4

      Standards
      IEEE 802.3 for 10BaseT
      IEEE 802.3u for 100BaseT(X)
      IEEE 802.3ab for 1000BaseT(X)
      IEEE 802.3x for flow control
      IEEE 802.1D-2004 for Spanning Tree Protocol
      IEEE 802.1w for Rapid Spanning Tree Protocol
      IEEE 802.1Q for VLAN Tagging
      IEEE 802.1p for Class of Service



    Ethernet Software Features

      Industrial Protocols
      EtherNet/IP
      Modbus TCP
      PROFINET IO Device

      Management
      Back Pressure Flow Control
      DHCP Client
      Fiber check
      Flow control
      IPv4/IPv6
      LLDP
      Port Mirror
      RMON
      SNMP Inform
      SNMPv1/v2c/v3
      Syslog

      MIB
      RFC1213
      Ethernet-like MIB
      IF MIB
      LLDP MIB
      Bridge MIB
      Q-BRIDGE MIB

      Redundancy Protocols
      RSTP
      STP
      MRP

      Security
      Broadcast storm protection
      HTTPS/SSL
      SNMPv3
      Port Lock
      Trust access control

      Time Management
      NTP Server/Client
      SNTP

      Filter
      802.1Q VLAN



    Rotary Switch Configuration

      Industrial Profile Mode

      Indicator Mode
      0 No function enabled via DIP switch (Default)
      1 PROFINET profile enabled
      2 PROFINET profile and DHCP client enabled
      3 EtherNet/IP profile enabled
      4 EtherNet/IP profile and DHCP client enabled
      5 Modbus TCP profile enabled
      6 Modbus TCP profile and DHCP client enabled
      7 - 9 Reserved (currently performs the same behavior as indicator 0)




    Switch Properties

      MAC Table Size
      8 K

      Max. No. of VLANs
      8

      VLAN ID Range VID
      1 to 4094

      Packet Buffer Size
      3 Mbits



    LED Interface

      LED Indicators
      PWR1, PWR2, STATE, FAULT, 10/100M (TP Port), 1000M (TP port), 10/100/1000M
      (Gigabit Combo port), smart PoE LED (SDS-G3006-4PoE-2GTXSFP(-T) models only)



    USB Interface

      Storage Port
      USB Type A (for ABC-02 only)



    Input/Output Interface

      Alarm Contact Channels
      1
      Relay output with current carrying capacity of 1 A @ 24 VDC

      Buttons
      Reset button

      Digital Input Channels
      1

      Digital Inputs
      +13 to +30 V for state 1
      -30 to +3 V for state 0
      Max. input current: 8 mA



    Power Parameters

      Connection
      2 removable 4-contact terminal block(s)

      Input Voltage
      12-48 VDC
      Redundant dual inputs

      Operating Voltage
      SDS-G3006(-T) models: 9.6 to 60 VDC
      SDS-G3006-2GTXSFP(-T) models: 9.6 to 60 VDC
      SDS-G3006-4PoE-2GTXSFP(-T) models: 9.6 to 57 VDC

      Input Current
      SDS-G3006(-T) models: 0.76 A max. 12-48 VDC
      SDS-G3006-2GTXSFP(-T) models: 0.98 A max. 12-48 VDC
      SDS-G3006-4PoE-2GTXSFP(-T) models: 0.85 A max. 12-48 VDC

      Power Budget
      Max. 120 W for total PD consumption @ 48 VDC input
      Max. 90 W for total PD consumption @ 24 VDC input
      Max. 45 W for total PD consumption @ 12 VDC input
      Max. 36 W for each PoE port

      Power Consumption (Max.)
      SDS-G3006(-T) models: 7.16 W
      SDS-G3006-2GTXSFP(-T) models: 9.11 W
      SDS-G3006-4PoE-2GTXSFP(-T) models: 11.34 W full loading without PDs? consumption

      Overload Current Protection
      Supported

      Reverse Polarity Protection
      Supported



    Physical Characteristics

      Housing
      Metal

      IP Rating
      IP40

      Dimensions
      SDS-G3006(-T): 20 x 135 x 111 mm (0.79 x 5.32 x 4.37 in)
      SDS-G3006-2GTXSFP(-T): 36 x 135 x 111 mm (1.42 x 5.32 x 4.37 in)
      SDS-G3006-4PoE-2GTXSFP(-T): 36 x 135 x 111 mm (1.42 x 5.32 x 4.37 in)

      Weight
      SDS-G3006(-T): 383g (0.84 lbs)
      SDS-G3006-2GTXSFP(-T): 718g (1.58 lbs)
      SDS-G3006-4PoE-2GTXSFP(-T): 779g (1.72 lbs)

      Installation
      DIN-rail mounting
      Wall mounting (with optional kit)



    Environmental Limits

      Operating Temperature
      Standard Models: -10 to 60°C (14 to 140°F)
      Wide Temp. Models: -40 to 75°C (-40 to 167°F)

      Storage Temperature (package included)
      -40 to 85°C (-40 to 185°F)

      Ambient Relative Humidity
      5 to 95% (non-condensing)



    Standards and Certifications

      EMC
      EN 55032/35
      EN 61000-6-2/-6-4

      EMI
      CISPR 32, FCC Part 15B Class A

      EMS
      IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV
      IEC 61000-4-3 RS: 80 MHz to 800 MHz: 10 V/m; 800 MHz to 1 GHz: 20 V/m
      IEC 61000-4-4 EFT: Power: 2 kV; Signal: 2 kV
      IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV (1.2/50 ?s), 1 kV (10/700 ?s)
      IEC 61000-4-6 CS: 10 V
      IEC 61000-4-8 PFMF

      Safety
      EN IEC 62368-1
      UL 61010-2-201

      Shock
      IEC 60068-2-27

      Freefall
      IEC 60068-2-32

      Vibration
      IEC 60068-2-6



    MTBF

      Time
      SDS-G3006(-T): 3,483,278 hrs
      SDS-G3006-2GTXSFP(-T): 3,196,539 hrs
      SDS-G3006-4PoE-2GTXSFP(-T): 2,339,356 hrs

      Standards
      Telcordia (Bellcore), GB



    Package Contents

      Device
      1 x SDS-G3006 Series switch

      Documentation
      1 x product certificates of quality inspection, Simplified Chinese
      1 x product notice, Simplified Chinese
      1 x quick installation guide
      1 x warranty card







Ordering Information


Model Name 10/100/1000BaseT(X)
Ports, RJ45 Connector
Combo Ports, 10/100/
1000BaseT(X) or 100/
1000BaseSFP
PoE 10/100/
1000BaseT(X) Ports,
RJ45 Connector
Operating Voltage Operating Temp.
SDS-G3006 6 - - 9.6 to 60 VDC -10 to 60°C
SDS-G3006-T 6 - - 9.6 to 60 VDC -40 to 75°C
SDS-G3006-2GTXSFP 4 2 - 9.6 to 60 VDC -10 to 60°C
SDS-G3006-2GTXSFP-T 4 2 - 9.6 to 60 VDC -40 to 75°C
SDS-G3006-4PoE-2GTXSFP, 4 2 4 9.6 to 57 VDC -10 to 60°C
SDS-G3006-4PoE-2GTXSFP-T 4 2 4 9.6 to 57 VDC -40 to 75°C