MOXA NPort W2150A-W4 / W2250A-W4

1- and 2-port serial-to-Wi-Fi (802.11a/b/g/n) device servers with a wireless client

MOXA NPort W2150A-W4 / W2250A-W4
7862_34083.png
7862_34084.jpg
7862_34085.jpg
7862_34086.jpg
7862_34087.jpg
7862_34088.jpg
7862_34089.jpg
7862_34090.png
  • EspecificacionesEspecificaciones
  • DescripciónDescripción
  • Más informaciónesMás informaciónes
  • PDFPDF
  • Links serial and Ethernet devices to an IEEE 802.11a/b/g/n network
  • Web-based configuration using built-in Ethernet or WLAN
  • Secure Boot that only allows Moxa-authorized firmware to run on devices
  • Remote configuration with HTTPS, SSH
  • Secure data access with WEP, WPA, WPA2
  • Fast roaming for quick automatic switching between access points
  • Offline port buffering and serial data log
  • Enhanced surge protection for serial, LAN, and power
  • Dual power inputs (1 screw-type power jack, 1 terminal block)
The NPort® W2150A-W4 and W2250A-W4 are the ideal choice for connecting your serial and Ethernet devices, such as PLCs, meters, and sensors, to a wireless LAN. Your communications software will be able to access the serial devices from anywhere over a wireless LAN. Moreover, the wireless device servers require fewer cables and are ideal for applications that involve difficult wiring situations. In Infrastructure Mode, the NPort® W2150A-W4 and NPort® W2250A-W4 can connect to Wi-Fi networks at offices and factories to allow users to move, or roam, between several APs (access points), and offer an excellent solution for devices that are frequently moved from place to place.

ProdGrafik

Specifications

    Ethernet Interface

      10/100BaseT(X) Ports (RJ45 connector)
      1

      Magnetic Isolation Protection
      1.5 kV (built-in)

      Standards
      IEEE 802.3 for 10BaseT
      IEEE 802.3u for 100BaseT(X)



    Ethernet Software Features

      Configuration Options
      Web Console (HTTP/HTTPS)
      Windows Utility

      Management
      DHCP Option 82
      HTTP
      IPv4
      SMTP
      SNMPv1/v2c/v3
      Syslog
      Telnet
      Web Console

      Windows Real COM Drivers
      Windows 95/98/ME/NT/2000, Windows XP/2003/Vista/2008/7/8/8.1/10/11 (x86/ x64),
      Windows 2008 R2/2012/2012 R2/2016/2019 (x64), Windows Server 2022, Windows XP Embedded

      Linux Real TTY Drivers
      Kernel versions: 2.4.x, 2.6.x, 3.x, 4.x, and 5.x

      Fixed TTY Drivers
      SCO UNIX, SCO OpenServer, UnixWare 7, QNX 4.25, QNX 6, Solaris 10,
      FreeBSD, AIX 5. x, HP-UX 11i, Mac OS X

      Android API
      Android 3.1.x and later

      MIB
      Device Settings MIB
      RFC1213, RFC1317

      Security
      HTTPS/SSL
      User Authentication Management: local database, RADIUS
      Secure Protocols: HTTPS (TLSv1.2), SSH, SNMPv3
      Cryptography: HMAC, SHA-1, SHA-256, SHA-384, RSA-1024, AES-128, AES-256

      Time Management
      NTP Client
      SNTP Client



    WLAN Interface

      WLAN Standards
      802.11a/b/g/n

      Receiver Sensitivity for 802.11a (measured at 5.680 GHz)
      Typ. -91 @ 6 Mbps
      Typ. -74 @ 54 Mbps

      Receiver Sensitivity for 802.11b (measured at 2.437 GHz)
      Typ. -92 dBm @ 1 Mbps
      Typ. -84 dBm @ 11 Mbps

      Receiver Sensitivity for 802.11g (measured at 2.437 GHz)
      Typ. -91 dBm @ 6 Mbps
      Typ. -73 dBm @ 54 Mbps

      Receiver Sensitivity for 802.11n (2.4 GHz; measured at 2.437 GHz)
      Typ. -89 dBm @ 6.5 Mbps (20 MHz)
      Typ. -71 dBm @ 72.2 Mbps (20 MHz)

      Receiver Sensitivity for 802.11n (5 GHz; measured at 5.680 GHz) Typ. -89 dBm @ 6.5 Mbps (20 MHz)
      Typ. -71 dBm @ 72.2 Mbps (20 MHz)
      Typ. -85 dBm @ 13.5 Mbps (40 MHz)
      Typ. -67 dBm @ 150 Mbps (40 MHz)

      Modulation Type
      DSSS
      OFDM

      Transmission Distance
      Up to 100 meters (in open areas)

      Transmission Rate
      802.11a/g: 54 Mbps
      802.11b: 11 Mbps
      802.11n: 6.5 to 150 Mbps

      Transmitter Power for 802.11b
      16±1.5 dBm @ 1 Mbps
      16±1.5 dBm @ 11 Mbps

      Transmitter Power for 802.11g
      16±1.5 dBm @ 6 Mbps
      14±1.5 dBm @ 54 Mbps

      Transmitter Power for 802.11a
      15±1.5 dBm @ 6 Mbps
      14±1.5 dBm @ 54 Mbps

      Transmitter Power for 802.11n (2.4 GHz)
      16 dBm @ 1.5 Mbps (6.5 MHz)
      12 dBm @ 1.5 Mbps (72.2 MHz)

      Transmitter Power for 802.11n (5 GHz)
      15 dBm @ 1.5 Mbps (6.5 MHz)
      12 dBm @ 1.5 Mbps (150 MHz)

      Frequency Band for CN (20 MHz operating channels)
      2.412 to 2.472 GHz (13 channels)
      5.180 to 5.240 GHz (4 channels)
      5.260 to 5.320 GHz (4 channels)1
      5.745 to 5.825 GHz (5 channels)

      Frequency Band for EU (20 MHz operating channels)
      2.412 to 2.472 GHz (13 channels)
      5.180 to 5.240 GHz (4 channels)
      5.260 to 5.320 GHz (4 channels)2
      5.500 to 5.700 GHz (11 channels)2

      Frequency Band for JP (20 MHz operating channels)
      2.412 to 2.472 GHz (13 channels)
      5.180 to 5.240 GHz (4 channels)
      5.260 to 5.320 GHz (4 channels)2
      5.500 to 5.700 GHz (11 channels)2

      Frequency Band for US (20 MHz operating channels)
      2.412 to 2.462 GHz (11 channels)
      5.180 to 5.240 GHz (4 channels)
      5.260 to 5.320 GHz (4 channels)2
      5.500 to 5.700 GHz (11 channels)2
      5.745 to 5.825 GHz (5 channels)

      Wireless Security
      WEP encryption (64-bit and 128-bit)
      WPA/WPA2-Enterprise (IEEE 802.1X/RADIUS, TKIP, AES)
      WPA/WPA2-Personal

      WLAN Modes
      Infrastructure mode



    Antenna Characteristics

      Connector
      RP-SMA (male)

      Antenna Type
      Omni-directional



    Security Functions

      Authentication
      Local database
      RADIUS

      Encryption
      AES-128
      AES-256
      HMAC
      RSA-1024
      SHA-1
      SHA-256
      SHA-384

      Security Protocols
      SNMPv3
      SSHv2
      HTTPS (TLS 1.2)

      Wireless Security
      WEP WPA/WPA2-Enterprise
      WPA/WPA2-Personal

      Hardware-based Security
      Secure Boot



    Serial Interface

      Connector
      DB9 male

      No. of Ports
      NPort W2150A-W4/W2150A-W4-T: 1
      NPort W2250A-W4/W2250A-W4-T: 2

      Serial Standards
      RS-232
      RS-422
      RS-485

      Operation Modes
      Real COM mode
      TCP Server mode
      TCP Client mode
      UDP mode
      RFC2217 mode
      Pair Connection mode
      Ethernet Modem mode
      Disabled

      Baudrate
      300 bps to 921.6 kbps

      Data Bits
      5, 6, 7, 8

      Stop Bits
      1, 1.5, 2

      Parity
      None, Even, Odd, Space, Mark

      Flow Control
      None
      RTS/CTS
      XON/XOFF

      RS-485 Data Direction Control
      ADDC® (automatic data direction control)

      Pull High/Low Resistor for RS-485
      1 kilo-ohm, 150 kilo-ohms

      Terminator for RS-485
      120 ohms

      Surge
      1 kV



    Physical Characteristics

      Housing
      Metal Installation
      Desktop
      DIN-rail mounting (with optional kit)
      Wall mounting

      Dimensions (with ears, without antenna)
      77 x 111 x 26 mm (3.03 x 4.37 x 1.02 in)

      Dimensions (without ears or antenna)
      100 x 111 x 26 mm (3.94 x 4.37 x 1.02 in)

      Weight
      NPort W2150A-W4/W2150A-W4-T: 185 g (0.41 lb)
      NPort W2250A-W4/W2250A-W4-T: 191 g (0.42 lb)

      Antenna Length
      108 mm (4.25
      in)



    Environmental Limits

      Operating Temperature
      Standard Models: 0 to 55°C (32 to 131°F)
      Wide Temp. Models: -40 to 75°C (-40 to 167°F)

      Storage Temperature (package included)
      -40 to 75°C (-40 to 167°F)

      Ambient Relative Humidity
      5 to 95% (non-condensing)



    Power Parameters

      Input Current
      NPort W2150A-W4/W2150A-W4-T: 429 mA @ 12 VDC
      NPort W2250A-W4/W2250A-W4-T: 455 mA @ 12 VDC

      Input Voltage
      12 to 48 VDC



    Standards and Certifications

      EMC
      EN 55032/35
      EMI CISPR 32, FCC Part 15B Class A

      EMS
      IEC 61000-4-2 ESD: Contact: 4 kV; Air: 8 kV
      IEC 61000-4-3 RS: 80 MHz to 1 GHz: 3 V/m
      IEC 61000-4-4 EFT: Power: 2 kV; Signal: 2 kV
      IEC 61000-4-5 Surge: Power: 2 kV; Signal: 1 kV
      IEC 61000-4-6 CS: 150 kHz to 80 MHz: 3 V/m; Signal: 3 V/m
      IEC 61000-4-8 PFMF
      IEC 61000-4-11

      Radio Frequency
      CE (ETSI EN 301 893, ETSI EN 300 328, ETSI EN 301489-1/-17), MIC, KC, RCM

      Safety
      UL 62368-1
      IEC 62368-1



    Reliability

      Alert Tools
      RTC (real-time clock)

      Automatic Reboot Trigger
      Built-in WDT



    MTBF

      Time
      NPort W2150A-W4/W2150A-W4-T: 1,356,464 hrs
      NPort W2250A-W4/W2250A-W4-T: 1,187,539 hrs

      Standards
      Telcordia SR332



  1. DFS (Dynamic Frequency Selection) channel support: In AP mode, when a radar signal is detected, the device will automatically switch to another channel. However, according to regulations, after switching channels, a 60-second availability check period is required before starting the service.
  2. DFS (Dynamic Frequency Selection) channel support: In AP mode, when a radar signal is detected, the device will automatically switch to another channel. However, according to regulations, after switching channels, a 60-second availability check period is required before starting the service.



Package Contents

    Device
    1 x NPort W2150A-W4/W2250A-W4 Series device server

    Power Supply
    1 x power adapter, suitable for your region (standard temp. models only)

    Antenna
    1 x 2.4/5 GHz antenna

    Documentation
    1 x quick installation guide
    1 x warranty card




Ordering Information

Model Name No. of serial ports WLAN Channels Input Current Operating Temp. Power Adapter in Box Notes
NPort W2150A-W4-CN 1 China bands 429 mA @ 12 VDC 0 to 55°C Yes (CN plug) -
NPort W2150A-W4-EU 1 Europe bands 429 mA @ 12 VDC 0 to 55°C Yes (EU/UK/AU plug) -
NPort W2150A-W4-EU/KC 1 Europe bands 429 mA @ 12 VDC 0 to 55°C Yes (KR plug) KC certificate
NPort W2150A-W4-JP 1 Japan bands 429 mA @ 12 VDC 0 to 55°C Yes (JP plug) -
NPort W2150A-W4-US 1 US bands 429 mA @ 12 VDC 0 to 55°C Yes (US plug) -
NPort W2150A-W4-T-CN 1 China bands 429 mA @ 12 VDC -40 to 75°C No -
NPort W2150A-W4-T-EU 1 Europe bands 429 mA @ 12 VDC -40 to 75°C No -
NPort W2150A-W4-T-JP 1 Japan bands 429 mA @ 12 VDC -40 to 75°C No -
NPort W2150A-W4-T-US 1 US bands 429 mA @ 12 VDC -40 to 75°C No -
NPort W2250A-W4-CN 2 China bands 455 mA @ 12 VDC 0 to 55°C Yes (CN plug) -
NPort W2250A-W4-EU 2 Europe bands 455 mA @ 12 VDC 0 to 55°C Yes (EU/UK/AU plug) -
NPort W2250A-W4-EU/KC 2 Europe bands 455 mA @ 12 VDC 0 to 55°C Yes (KR plug KC certificate
NPort W2250A-W4-JP 2 Japan bands 455 mA @ 12 VDC 0 to 55°C Yes (JP plug) -
NPort W2250A-W4-US 2 US bands 455 mA @ 12 VDC 0 to 55°C Yes (US plug) -
NPort W2250A-W4-T-CN 2 China bands 455 mA @ 12 VDC -40 to 75°C No -
NPort W2250A-W4-T-EU 2 Europe bands 455 mA @ 12 VDC -40 to 75°C No -
NPort W2250A-W4-T-JP 2 Japan bands 455 mA @ 12 VDC -40 to 75°C No -
NPort W2250A-W4-T-U 2 US bands 455 mA @ 12 VDC -40 to 75°C No -



Accessories (sold separately)

Antennas
ANT-WDB-ASM-03 BK 2 dBi at 2.4 GHz or 2 dBi at 5 GHz, RP-SMA (male) omnidirectional rubber-duck antenna
Cables
CBL-F9M9-150 DB9 female to DB9 male serial cable, 1.5 m
CBL-F9M9-20 DB9 female to DB9 male serial cable, 20 cm
Connectors
ADP-RJ458P-DB9F DB9 female to RJ45 connector
Mini DB9F-to-TB DB9 female to terminal block connector
DIN-Rail Mounting Kits
DK35A DIN-rail mounting kit, 35 mm
Power Adapters
PWR-12050-AU-S1 Locking barrel plug, 12 VDC, 0.5 A, 100 to 240 VAC, AU plug, 0 to 40°C operating temperature
PWR-12050-CN-S1 Locking barrel plug, 12 VDC, 0.5 A, 100 to 240 VAC, CN plug, 0 to 40°C operating temperature
PWR-12050-EU-S1 Locking barrel plug, 12 VDC, 0.5 A, 100 to 240 VAC, EU plug, 0 to 40°C operating temperature
PWR-12050-UK-S1 Locking barrel plug, 12 VDC, 0.5 A, 100 to 240 VAC, UK plug, 0 to 40°C operating temperature
PWR-12050-USJP-S1 Locking barrel plug, 12 VDC, 0.5 A, 100 to 240 VAC, US/JP plug, 0 to 40°C operating temperature
PWR-12050-KR-S1 Locking barrel plug, 12 VDC, 0.5 A, 100 to 240 VAC, KR plug, 0 to 40°C operating temperature
PWR-12150-AU-SA-T Locking barrel plug, 12 VDC, 1.5 A, 100 to 240 VAC, AU plug, -40 to 75°C operating temperature
Applicable Models:
NPort W2150A-W4-T-CN
NPort W2150A-W4-T-EU
NPort W2150A-W4-T-JP
NPort W2150A-W4-T-US
NPort W2250A-W4-T-CN
NPort W2250A-W4-T-EU
NPort W2250A-W4-T-JP
NPort W2250A-W4-T-US
PWR-12150-CN-SA-T Locking barrel plug, 12 VDC, 1.5 A, 100 to 240 VAC, CN plug, -40 to 75°C operating temperature
Applicable Models:
NPort W2150A-W4-T-CN
NPort W2150A-W4-T-EU
NPort W2150A-W4-T-JP
NPort W2150A-W4-T-US
NPort W2250A-W4-T-CN
NPort W2250A-W4-T-EU
NPort W2250A-W4-T-JP
NPort W2250A-W4-T-US
PWR-12150-EU-SA-T Locking barrel plug, 12 VDC, 1.5 A, 100 to 240 VAC, EU plug, -40 to 75°C operating temperature
Applicable Models:
NPort W2150A-W4-T-CN
NPort W2150A-W4-T-EU
NPort W2150A-W4-T-JP
NPort W2150A-W4-T-US
NPort W2250A-W4-T-CN
NPort W2250A-W4-T-EU
NPort W2250A-W4-T-JP
NPort W2250A-W4-T-US
PWR-12150-UK-SA-T Locking barrel plug, 12 VDC, 1.5 A, 100 to 240 VAC, UK plug, -40 to 75°C operating temperature
Applicable Models:
NPort W2150A-W4-T-CN
NPort W2150A-W4-T-EU
NPort W2150A-W4-T-JP
NPort W2150A-W4-T-US
NPort W2250A-W4-T-CN
NPort W2250A-W4-T-EU
NPort W2250A-W4-T-JP
NPort W2250A-W4-T-US
PWR-12150-USJP-SA-T Locking barrel plug, 12 VDC 1.5 A, 100 to 240 VAC, US/JP plug, -40 to 75°C operating temperature
Applicable Models:
NPort W2150A-W4-T-CN
NPort W2150A-W4-T-EU
NPort W2150A-W4-T-JP
NPort W2150A-W4-T-US
NPort W2250A-W4-T-CN
NPort W2250A-W4-T-EU
NPort W2250A-W4-T-JP
NPort W2250A-W4-T-US
Power Cords
CBL-PJ21NOPEN-BK-30 Locking barrel plug to bare-wire cable


Los clientes que han visto este artículo también vieron
Accept

This website uses cookies to provide the best possible experience. More information.