MOXA MGate 4101-MB-PBS

SPHINX en Europe
ES
  • AT
  • BE
  • DK
  • FR
  • DE
  • IE
  • IT
  • NL
  • ES
  • SE
  • CH
  • UK
Productos grupos > Gateways > MOXA MGate 4101-MB-PBS

MOXA MGate 4101-MB-PBS

1-port Modbus RTU/ASCII to PROFIBUS slave gateways

MOXA MGate 4101-MB-PBS
4458_12624.png
4458_9752.png
4458_9753.png
  • EspecificacionesEspecificaciones
  • DescripciónDescripción
  • Más informaciónesMás informaciónes
  • PDFPDF
  • Protocol conversion between Modbus and PROFIBUS
  • Windows utilities with innovative QuickLink function for automatic configuration within minutes
  • Redundant dual DC power inputs and relay output supported
  • Embedded data packet analyzer
  • Powerful and visual diagnostic tool
  • -40 to 75°C wide operating temperature models available
The MGate 4101-MB-PBS gateway provides a communication portal between PROFIBUS PLCs (e.g. Siemens S400 and S300 PLCs) and Modbus devices. With the QuickLink feature, I/O mapping can be accomplished within a matter of minutes. All models are protected with a rugged metallic casing, are DIN-rail mountable, and offer optional built-in optical isolation.

Windows Utilities for Easy Setup and Traffic Monitoring

The QuickLink windows utility uses a serial console port to connect to the MGate 4101-MB-PBS and makes configuration and operation as easy as possible. QuickLink can finish configuration in just few minutes by passively detecting Modbus requests with the AutoLearning function, and performing error-free I/O mapping with the AutoMapping feature. QuickLink drastically reduces Modbus-to-PROFIBUS integration time when compared to conventional I/O mapping, which can easily require days to complete. Additionally, embedded monitoring tools can maintain logs of Modbus communication packets and assist in troubleshooting.

Redundant Power Inputs

The MGate 4101-MB-PBS has dual power inputs for greater reliability. The power inputs allow simultaneous connections to two live DC power sources, so that continuous operation is provided even if one power source fails. The higher level of reliability makes these advanced Modbus-to-PROFIBUS gateways ideal for demanding industrial applications.

Warning by Relay Output

A relay output is provided for the power input status. The relay output gives maintenance engineers an additional tool for troubleshooting and maintenance.

ProdGrafik
PROFIBUS Interface

    Protocol
    PROFIBUS DP-V0 Slave

    Number of Ports
    1

    Data Rate
    9600 bps to 12 Mbps

    Connector
    DB9 female

    Isolation
    2 kV (built-in)

    DIP Switch
    For termination

    Rotary Switch
    PROFIBUS address 0-99 (address 100-125 supported through software configuration)


Modbus Interface

    Protocol
    Modbus RTU/ASCII Slave/Master

    Number of Ports
    1

    Serial Standards
    RS-232/422/485, software selectable

    Connectors
    DB9 male

    ESD Protection
    15 kV for all signals

    RS-485 Data Direction Control
    ADDC® (automatic data direction control)

    Pull High/Low Resistor for RS-485
    1 kÙ, 150 kÙ

    Terminator for RS-485
    120 Ù

    Data Bits
    7, 8

    Stop Bits
    1, 2

    Parity
    None, Even, Odd, Space, Mark

    Flow Control
    RTS/CTS, DTR/DSR (RS-232 only)

    Baudrate
    50 bps to 921.6 kbps


Serial Signals

    RS-232
    TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND

    RS-422
    Tx+, Tx-, Rx+, Rx-, GND

    RS-485-4w
    Tx+, Tx-, Rx+, Rx-, GND

    RS-485-2w
    Data+, Data-, GND


Software

    Configuration Options
    Serial Console, Windows Utility

    Utilities
    MGate Manager for Windows 2000/XP/2003/Vista/Server 2008/7/8 (x86/x64), Windows Server 2008 R2/2012 (x64)

    Support
    QuickLink, Paging


Physical Characteristics

    Housing
    Metal, IP30 protection

    Weight
    500 g

    Dimensions
    36 x 105 x 140 mm (1.42 x 4.14 x 5.51 in)


Environmental Limits

    Operating Temperature
    Standard Models: 0 to 60°C (32 to 140°F)

    Wide Temp. Models:
    -40 to 75°C (-40 to 167°F)

    Storage Temperature
    -40 to 85°C (-40 to 185°F)

    Ambient Relative Humidity
    5 to 95% (non-condensing)

    Altitude
    Up to 2000 m (795 hPa), higher altitudes on demand

    Note
    Please contact usif you require products guaranteed to function properly at higher altitudes.


Power Requirements

    Input Voltage
    12 to 48 VDC

    Power Connector
    Terminal block

    Power Consumption
    MGate 4101-MB-PBS: 340 mA @ 12 VDC, 130 mA @ 48 VDC
    MGate 4101I-MB-PBS: 375 mA @ 12 VDC, 140 mA @ 48 VDC


Standards and Certifications

    Safety
    UL 60950-1, EN 60950-1

    Hazardous Location
    UL/cUL Class 1 Division 2 Groups A/B/C/D (Pending),
    ATEX Zone 2 Ex nA nC IIC T3 Gc (Pending),
    IECEx (Pending)

    EMC
    CE, FCC

    EMI
    EN 55022 Class A, FCC Part 15 Subpart B Class A

    EMS
    EN 55024,
    EN 61000-4-2 (ESD) Level 3,
    EN 61000-4-3 (RS) Level 2,
    EN 61000-4-4 (EFT) Level 3,
    EN 61000-4-5 (Surge) Level 3,
    EN 61000-4-6 (CS) Level 2,
    EN 61000-4-8 (PFMF) Level 1

    Shock
    IEC 60068-2-27

    Freefall
    IEC 60068-2-32

    Vibration
    IEC 60068-2-6


Reliability

    MTBF (mean time between failures)
    513,139 hrs


Ordering Information

           Available Modules
MGate 4101-MB-PBS 1-port Modbus to PROFIBUS Slave gateway, 12-48 VDC, 0 to 60°C operating temperature
MGate 4101I-MB-PBS 1-port Modbus to PROFIBUS Slave gateway with 2 KV Isolation, 12-48 VDC, 0 to 60°C operating temperature
MGate 4101-MB-PBS-T 1-port Modbus to PROFIBUS Slave gateway, 12-48 VDC, -40 to 75°C operating temperature
MGate 4101I-MB-PBS-T 1-port Modbus to PROFIBUS Slave gateway with 2 KV Isolation, 12-48 VDC, -40 to 75°C operating temperature



Los clientes que han visto este artículo también vieron
Accept

This website uses cookies to provide the best possible experience. More information.