PERLE IOLAN STS DC Rack

Console Servers 48vDC

PERLE IOLAN STS DC Rack
4445_23950.png
4445_23951.jpg
4445_23952.jpg
4445_23953.jpg
  • EspecificacionesEspecificaciones
  • DescripciónDescripción
  • Más informaciónesMás informaciónes
  • PDFPDF
  • 4, 8 or 16 serial RS232 on RJ45 Ports
  • 10/100/1000 Ethernet
  • Dual Feed 48v DC power ( 36 to 72v DC range )
  • Advanced security feature set

Telecommunications Engineers and Project Managers that require a cost effective serial-to-Ethernet solution for 48vDC environments such as Telco substations and switching centers must consider the IOLAN STS 48v DC Rack. Having the highest performance processor available along with its unique TrueSerial™ technology, the IOLAN STS DC Rack will provide the most authentic serial connections across Ethernet.

Ideal for

  • Telecommunications Engineers and Project Managers requiring a high performance serial to Ethernet interface for 4 to 16 serial RS232 based data acquisition devices
  • IT Professionals requiring a cost-effective terminal server or serial console server for out-of-band management of IT equipment in 48vDC environments


Why IOLAN STS DC Rack models are the preferred choice:

  • High performance 400 Mhz, 750 MIPS, 32 bit processor with integrated hardware encryption processor for the best throughput on the market. Ideal for time sensitive applications
  • Next Generation IP support (IPv6) for investment protection and network compatibility
  • TrueSerial™ packet technology – the most authentic serial connections across Ethernet ensures serial protocol integrity
  • Primary/Backup host functionality enables automatic connections to alternate hosts should the primary TCP connection go down
  • EasyPort Web – Access equipment serial console ports by using your java-enabled Internet browser
  • TruePort – Perle’s com/tty redirector for serial based applications operates on Windows, Vista, Linux, Solaris, SCO and Unix
  • Clustering – Provides a single view of all out of band console ports. Ideal for large data centers
  • FIPS 140-2 – Cryptographic modules meet US Government NIST compliancy
  • Dynamic DNS – Easy console management access from anywhere on the Internet
  • Java-free browser access to remote serial console ports via Telnet and SSH
  • Ping watchdog probes enable customers to power cycle equipment with attached Perle RPS power switches in the event of an unresponsive networking gear
  • Lifetime warranty – best investment protection available


ProdGrafik

Serial Port Access

    Connect directly using Telnet / SSH by port and IP address
    Connect with EasyPort menu by Telnet / SSH
    Use an internet browser to access with HTTP or secure https via EasyPort Web menu
    Java-free browser access to remote serial console ports via Telnet and SSH
    Ports can be assigned a specific IP address ( aliasing )
    Multisession capability enables multiple users to access ports simultaneously
    Multihost access enables multiple hosts/servers to share serial ports


Accessibility

    In-band ( Ethernet ) and out-of-band ( dial-up modem ) support
    Dynamic DNS enables users to find a console server from anywhere on the Internet
    Domain name control through DHCP option 81
    IPV6 and IPV4 addressing support


Availability

    Primary/Backup host functionality enables automatic connections to alternate host(s)


Security

    SSH v1 and v2
    SSL V3.0/TLS V1.0, SSL V2.0
    SSL Server and SSL client mode capability
    SSL Peer authentication
    IPSec VPN : NAT Traversal, ESP authentication protocol
    Encryption: AES (256/192/128), 3DES, DES, Blowfish, CAST128, ARCFOUR(RC4), ARCTWO(RC2)
    Hashing Algorithms: MD5, SHA-1, RIPEMD160, SHA1-96, and MD5-96
    Key exchange: RSA, EDH-RSA, EDH-DSS, ADH
    X.509 Certificate verification: RSA, DSA
    Certificate authority (CA) list
    Local database
    RADIUS Authentication, Authorization and Accounting
    TACACS+ Authentication, Authorization and Accounting
    LDAP, NIS, Kerberos Authentication
    RSA SecureID-agent or via RADIUS Authentication
    SNMP v3 Authentication and Encryption support
    IP Address filtering
    Disable unused daemons
    Active Directory via LDAP


Terminal Server

    Telnet
    SSH v1 and v2
    Rlogin
    Auto session login
    LPD, RCP printer
    MOTD - Message of the day


Serial machine to Ethernet

    Tunnel raw serial data across Ethernet - clear or encrypted
    Raw serial data over TCP/IP
    Raw serial data over UDP
    Serial data control of packetized data
    Share serial ports with multiple hosts/servers
    Virtual modem simulates a modem connection - assign IP address by AT phone number
    Virtual modem data can be sent over the Ethernet link with or without SSL encryption
    TruePort com/tty redirector for serial based applications on Windows, Linux, Solaris, SCO, HP UX, NCR UNIX and AIX.
    TrueSerial packet technology provides the most authentic serial connections across Ethernet ensuring serial protocol integrity
    RFC 2217 standard for transport of serial data and RS232 control signals
    Customizable or fixed serial baud rates
    Plug-ins allow customer or Perle provided plug-ins for special applications
    Software Development Kit ( SDK ) available
    Serial encapsulation of industrial protocols such as ModBus, DNP3 and IEC-870-5-101
    ModBus TCP gateway enables serial Modbus ASCII/RTU device connection to ModBus TCP
    Data logging will store serial data received when no active TCP session and forward to network peer once session re-established - 32K bytes circular per port


Console Management

    Sun / Oracle Solaris Break Safe
    Local port buffer viewing - 256K bytes per port
    External port buffering via NFS, encrypted NFS and Syslog
    Event notification
    Manage AC power of external equipment using Perle RPS power management products
    Clustering - central console server enables access ports across multiple console servers
    Windows Server 2003/2008 EMS - SAC support GUI access to text-based Special Administrative Console
    Ping watchdog probes enable customers to power cycle equipment with attached Perle RPS power switches in the event of an unresponsive networking gear


Remote Access

    Dial, direct serial
    PPP, PAP/CHAP, SLIP

    HTTP tunneling enables firewall-safe access to remote serial devices across the internet

    Automatic DNS Update
    Utilize DHCP Opt 81 to set IOLAN domain name for easy name management and with Dynamic DNS support , users on the Internet can access the device server by name without having to know its IP address. See Automatic DNS update support for details

    IPSEC VPN client/servers
    Microsoft L2TP/IPSEC VPN client ( native to Windows XP)
    Microsoft IPSEC VPN Client ( native to Windows Vista )
    Cisco routers with IPSEC VPN feature set
    Perle IOLAN SDS/STS and SCS models


OA&M ( Operations, Administration and Management )

    SNMP V3 - read and write, Perle MIB
    Syslog
    Perle Device Manager - Windows based utility for large scale deployments
    Configurable default configuration
    Installation Wizard
    Set a Personalized Factory Default for your IOLANs


Protocols

    IPv6, IPv4, TCP/IP, Reverse SSH, SSH, SSL, IPSec/IPv4, IPSec/IPv6, L2TP/IPSec, CIDR, RIPV2/MD5, ARP, RARP, UDP, UDP Multicast, ICMP, BOOTP, DHCP, TFTP, SFTP, SNTP, Telnet, raw, reverse Telnet, LPD, RCP, DNS, Dynamic DNS, WINS, HTTP, https, SMTP, SNMPV3, PPP, PAP/CHAP, SLIP, CSLIP, RFC2217, MSCHAP



Hardware Specifications - IOLAN STS 48v DC Rack, RS232 Serial Terminal Servers

  IOLAN STS4 DC IOLAN STS8 DC IOLAN STS16 DC
Processor MPC8349E, 400 Mhz, 750 MIPS
Memory
RAM MB 32 64 64
Flash MB 16 16 16
Interface Ports
Number of Serial Ports 4 8 16
Serial Port Interface RS232 DTE on RJ45
Sun / Solaris Sun / Oracle ‘Solaris' Safe - no "break signal" sent during
power cycle causing costly server re-boots or downtime
Serial Port Speeds 50bps to 230Kbps with customizable baud rate support
Data Bits 5,6,7,8, 9-bit protocol support
Parity Odd, Even, Mark, Space, None
Flow Control Hardware, Software, Both, None
Serial Port Protection 15Kv Electrostatic Discharge Protection ( ESD )
Local Console Port RS232 on RJ45 with DB9 adapter ( provided )
Network 10/100/1000-base TX Ethernet RJ45
Software selectable Ethernet speed 10/100/1000, Auto
Software selectable Half/Full/Auto duplex
Ethernet Isolation 1.5Kv Magnetic Isolation
Power
Power Supply 48 VDC
Input Voltage Range 36-72 VDC
Current Consumption @ 36v ( Amps ) 0.25 0.25 0.28
Current Consumption @ 48v ( Amps ) 0.19 0.19 0.21
Current Consumption @ 72v ( Amps ) 0.13 0.13 0.14
Typical Power Consumption ( Watts ) 9 9 10
Power Line Protection Fast transients: 1 KV (EN61000-4-4 Criteria B)
Surge: 2KV (EN61000-4-5 common mode), 1KV (EN61000-4-5 differential and common modes)
Indicators
LEDs Power
System Ready
Network Link activity
Serial: Transmit and Receive data per port
Environmental Specifications
Heat Output
( BTU/HR )
31 31 34
MTBF ( Hours )* 120917 118622 112256
Operating Temperature 0C to 55C, 32F to 131F
Storage Temperature -40C to 85C, -40F to 185F
Humidity 5 to 95% (non condensing) for both storage and operation.
Ingress Protection Rating IP30
Mounting 1U - 19" rack, front and rear mounting hardware included
Product Weight and Dimensions
Weight 2.7 kg 3 kg 3 kg
Dimensions 26.4 x 43.4 x 4.4 (cm), 10.38 x 17.1 x 1.75 (in)
Packaging
Shipping Dimensions 59 x 36 x 9cm
Shipping weight 3.9 kg 3.9 kg 4.0 kg
Regulatory Approvals
Emissions FCC Part 15, Subpart B, Class A
CFR47:2003, Chapter 1, Part 15 Subpart B,(USA) Class A
ICES-003, Issue 4, February 2004 (Canada)
EN55022:1998 + A1:2000 + A2:2003 Class A
EN61000-3-2 : 1995, Limits for Harmonic Current Emissions
EN61000-3-3 : 1995, Limits of Voltage Fluctuations and Flicker
Immunity EN55024:1998 + A1:2001 + A2:2003
EN61000-4-2: Electrostatic Discharge
EN61000-4-3: RF Electromagnetic Field Modulated
EN61000-4-4: Fast Transients
EN61000-4-5: Surge
EN61000-4-6: RF Continuous Conducted
EN61000-4-8: Power-Frequency Magnetic Field
EN61000-4-11: Voltage Dips and Voltage Interruptions
Safety IEC 60950-1 : 2005 (2nd Edition) + A1 : 2009 and
EN 60950-1 : 2006 + A11 : 2009
CAN/CSA-C22.2 No. 60950-1-03 and ANSI/UL 60950-1,
First Edition April 1st 2003 (Recognized Component)
Other Reach, RoHS and WEEE Compliant
CCATS - G168387
ECCN - 5A992
HTSUS Number: 8471.80.1000
Perle Limited Lifetime Warranty

  IOLAN DTE 

  RJ45Socket 

  RJ45 Socket


 IOLAN RJ45 Socket   Function    Direction 
1 DCD larrow
2 RTS right arrow
3 DSR larrow
4 TXD right arrow
5 RXD larrow
6 GND line
7 CTS larrow
8 DTR right arrow

Optional Perle adapters for use with straight thru CAT5 cabling


*Calculation model based on MIL-HDBK-217-FN2 @ 30 °C





TCP

Using RAW TCP Sockets

A raw TCP socket connection which can be initiated from the serial-Ethernet device or from the remote host/server. This can either be on a point to point or shared basis where a serial device can be shared amongst multiple devices. TCP sessions can be initiated either from the TCP server application or from the Perle IOLAN serial-Ethernet adapter.

 
UDP

Using Raw UDP Sockets

For use with UDP based applications, Perle IOLANs can convert serial equipment data for transport across UDP packets either on a point to point basis or shared across multiple devices.

 
Console Server

Console Management

For access to remote console ports on routers, switches,etc, Perle IOLAN’s enable administrators secure access to these RS232 ports via inband Reverse Telnet / SSH or out of band with dial-up modems. Perle IOLAN models with integrated modems are available.

 
COM/TTY

Connect Serial-based Applications with a COM/TTY Port Driver

Serial ports can be connected to network servers or workstations running Perle's TruePort software operating as a virtual COM port. Sessions can be initiated either from the Perle IOLAN or from TruePort.

 
Tunneling

Serial Tunneling between two Serial Devices

Serial Tunneling enables you to establish a link across Ethernet to a serial port on another IOLAN. Both IOLAN serial ports must be configured for Serial Tunneling (typically one serial port is configured as a Tunnel Server and the other serial port as a Tunnel Client).

 
Virtual Modem

Virtual Modem

Enables the serial-Ethernet adapter to simulate a modem connection. When connected to the IOLAN and initiates a modem connection, the IOLAN starts up a TCP connection to another IOLAN serial-Ethernet adapter configured with a Virtual Modem serial port or to a host running a TCP application.

 



Ordering Information

           Available Modules
IOLAN STS4 DC 4 x RJ45 serial ports, 10/100/1000 Ethernet,
1U rack mount, 48VDC power, RS232 interface, advanced feature set
IOLAN STS8 DC 8 x RJ45 serial ports, 10/100/1000 Ethernet,
1U rack mount, 48VDC power, RS232 interface, advanced feature set
IOLAN STS16 DC       16 x RJ45 serial ports, 10/100/1000 Ethernet,
1U rack mount, 48VDC power, RS232 interface, advanced feature set