MOXA CB-602I

SPHINX en Europe
ES
  • AT
  • BE
  • DK
  • FR
  • DE
  • IE
  • IT
  • NL
  • ES
  • SE
  • CH
  • UK
Productos grupos > CAN Interface Boards > MOXA CB-602I

MOXA CB-602I

2-port CAN interface PC/104-Plus module with 2 KV isolation

MOXA CB-602I
2669_12125.png
2669_8431.png
  • EspecificacionesEspecificaciones
  • DescripciónDescripción
  • Más informaciónesMás informaciónes
  • PDFPDF
  • CAN 2 .0A and CAN 2.0B supported
  • Two independent CAN communication ports
  • CAN transfer rate up to 1 Mbps
  • 2 KV optical isolation protection
  • LED for transmit/receive status on each port
  • Optional 120 ohm terminal resistor for CAN bus network
  • DLL library and examples included
  • Windows driver provided
Moxa’s new CB-602I CAN (Controller Area Network) interface board supports the PC/104-Plus interface. Optional DB9 and DB25 connection cables are available for connecting to CAN interface device. The CB-602I CAN interface board uses the NXP SJA1000 and transceiver PCA82C251, which provide the bus arbitration and error detection. The -40 to 85°C wide operating temperature (CB-602I-T only) and 2 KV isolation make the boards suitable for use in harsh industrial environments.
ProdGrafik

Hardware

Connector
20-pin box header

CAN Controller
NXP SJA1000

CAN Transceiver
PCA82C251

CAN Specification
CAN 2.0 A/B

Signal Support
CAN_H, CAN_L, GND

Transfer Rate
1 Mbps

Max. Number of Boards per PC
4

Electrical Isolation
2 kV

Termination Resistor
120 ohms (selected by jumper)


Driver Support

Operating Systems
Windows 2000, Windows XP/2003/Vista/2008 (x86/x64)

Linux Real TTY Drivers
Linux 2.6.x, 3.x


Software

Libraries
Visual C/C++, Borland C/C++


Environmental Limits

Operating Temperature
Standard Models: 0 to 55°C (32 to 131°F)

Wide Temp. Models:
-40 to 85°C (-40 to 185°F)

Storage Temperature
-40 to 85°C (-40 to 185°F)

Ambient Relative Humidity
5 to 95% (non-condensing)

Altitude
Up to 2000 m
Note Please contact us if you require products guaranteed to function properly at higher altitudes.


Standards and Certifications

EMC
CE, FCC

EMI
EN 61000-3-3, FCC Part 15 Subpart B Class B

EMS
IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11 (DIPS)

Green Product
RoHS, CRoHS, WEEE


MTBF (mean time between failures)

Time
248,563 hrs

Database
Telcordia (Bellcore), GB


Power Requirements

Power Consumption 380 mA @ 5 VDC





Ordering Information
CB-602I: 2-port CAN interface PC/104-Plus module with 2 KV optical isolation protection, 0 to 55°C operating temperature
CB-602I-T: 2-port CAN interface PC/104-Plus module with 2 KV optical isolation protection, -40 to 85°C operating temperature


Los clientes que han visto este artículo también vieron
Accept

This website uses cookies to provide the best possible experience. More information.